Warning: Division by zero in /var/www/u1611379/data/www/pocvoda.com/system/storage/modification/catalog/controller/product/product.php on line 411 Vesselin® Drug Coated Coronary Balloon Catheter - buy Coronary Balloons - wholesale prices from POCVODA

Vesselin® Drug Coated Coronary Balloon Catheter

Manufacturer Lepu

Safe and effective Drug dose, drug releasing keeps continuously and stably.

US $0
Payment

Delivery
Send inquiry

Vesselin® Drug Coated Coronary Balloon Catheter Details

Product Description  

Indications:

• Recommended for the treatment of stent restenosis, small vessel disease, and branch lesions.

• Clinical evidence supports primary coronary artery lesions such as macrovascular lesions.

Materials

• Improved PEBAX guarantees higher flexibility and enhanced crossability

Drug

• Loaded Paclitaxel inhibits restenosis continuously.

Drug Coating

• Coated with Active Pharmaceutical Ingredients grade urea, provide better biocompatibility, facilitate drug-releasing effectively.

Delivery system

• Spiral cut hypotube design, strengthen the transition section, bring optimized deliverability for transition.

Product Features


vesselin-drug-coated-coronary-balloon-catheter-1.jpg

Drug Coating

Coating with Active Pharmaceutical Ingredients grade urea, provide better biocompatibility, facilitate drug-releasing electively. Drug release rate in vivo achieves more than 90%.

The suitable particle size at 2-3µm, enables long term efficacy and low embolism risk

Drug

Paclitaxel loaded with drug dose at 3µg/mm², inhibits restenosis continuously

Delivery System

Spiral cut hypotube design, strengthens the transition section, brings optimized deliverability for transition.

Materials

Improved PEBAX material, lower crossing profile guarantees higher flexibility and enhanced crossability.



Technique Parameters

Balloon Material: PEBAX  

Euective length: 1350mm  

Distal Shaft O.D.: 2.7F

Balloon crossing profile: 0.026'' - 0.035''  

Guiding catheter compatibility: 5F and above  

Guide wire compatibility: 0.014''

Balanced safety and effectiveness

Compared with the control group, no significant difference in late lumen loss in

the segment in 9 months, thrombosis and TLF in 12 months.(TLF: Target lesion failure)

Vesselin Drug Coated Coronary Balloon Catheter Details

Lepu_Medical_Vesselin®_Drug_Eluting_Balloon_Company,_Drug_Coated_Balloon_Coronary-3.jpg

Drug balloon manipulation procedures instruction 


Vesselin



Specifications

Ordering Information

Diameter
(mm)
Length (mm)
912141618202428313538
2.0LPCDB
20009
LPCDB 20012LPCDB
20014
LPCDB
20016
LPCDB
20018
LPCDB
20020
LPCDB
20024
LPCDB
20028
LPCDB
20031
LPCDB
20035
LPCDB
20038
2.5LPCDB
25009
LPCDB
25012
LPCDB
25014
LPCDB
25016
LPCDB
25018
LPCDB
25020
LPCDB
25024
LPCDB
25028
LPCDB
25031
LPCDB
25035
LPCDB
25038
2.75LPCDB
27009
LPCDB
27012
LPCDB
27014
LPCDB
27016
LPCDB
27018
LPCDB
27020
LPCDB
27024
LPCDB
27028
LPCDB
27031
LPCDB
27035
LPCDB
27038
3LPCDB
30009
LPCDB
30012
LPCDB
30014
LPCDB
30016
LPCDB
30018
LPCDB
30020
LPCDB
30024
LPCDB
30028
LPCDB
30031
LPCDB
30035
LPCDB
30038
3.5LPCDB
35009
LPCDB
35012
LPCDB
35014
LPCDB
35016
LPCDB
35018
LPCDB
35020
LPCDB
35024
LPCDB
35028
LPCDB
35031
LPCDB
35035
LPCDB
35038
4.0LPCDB
40009
LPCDB
40012
LPCDB
40014
LPCDB
40016
LPCDB
40018
LPCDB
40020
LPCDB
40024
LPCDB
40028
LPCDB
40031
LPCDB
40035
LPCDB
40038
4.5LPCDB
45009
LPCDB
45012
LPCDB
45014
LPCDB
45016
LPCDB
45018
LPCDB
45020
LPCDB
45024
LPCDB
45028
LPCDB
45031
LPCDB
45035
LPCDB
45038

Related Products